This Anti-Cracking non-halogen, low smoke, highly flame retardant, low corrosive, low toxic, and thermoplastic compound is designed for general-purpose cable sheath applications. Used as sheath, it can pass the IEC60332-3, test for vertical flame spread of vertically mounted bunched wires or cables. Cable construction, of course, plays an important role in flame performance. It can be used as a sheath on cables operating at up to 90℃ with excellent fire safety characteristics and a good balance of properties. It is suitable for the power cable, especially big specification low-smoke nonhalogen flame-retardant power cable which lays down in the non-open-air situation.
-Excellent Anti-Cracking characteristic
- Highly flame retardant
- Low smoke, low corrosion and low toxicity
- Ease of extrusion and no special screw required
- Environmentally friendly (lead free, halogen-free, sulfur/antimony-free)
- UV resistant
Properties | Units | Typcal Value | Test Method |
Density | g/cm3 | 1.48 | ASTM D-792 |
Shore A/D hardness(15s/1s) | A/D | 95/51 | IEC 60811-1-3 |
Tensile strength | MPa | 12.0 | IEC 60811-1-1 |
Elongation at break | % | 190 | IEC 60811-1-1 |
After ageing in air oven (100℃×168 h) | IEC 60811-1-2 | ||
-Tensile strength | MPa | 13.6 | |
-Elongation at break | % | 170 | |
Heat deformation (90℃×4 h) | % | 8 | BS 6469 |
Heat shock test | ℃ | 150℃ Pass | IEC 60811-3-1 |
Cold impact test | ℃ | 25℃ Pass | ISO 974 |
Anti-Cracking test | No crack | 130℃×5kg×1h | |
Volume resistivity at 20 ℃ | Ω·m | 3.6×1011 | IEC 60093 |
Dielectric strength | MV/m | 30 | IEC 60243-1 |
Limited oxygen index | 35 | ISO 4589-2 | |
Smoke density – flame | 94 | ASTM E662 | |
-non-flame | 340 | ||
Acidic(corrosive)gases evolved | |||
-Level of HCl | mg/g | 0 | IEC 60754-1 |
-pH | 6.0 | IEC 60754-2 | |
-Conductivity | µS/mm | 0.62 |
Zoon | Feeder | Ⅰ | Ⅱ | Ⅲ | Ⅳ | Head (Die) |
Temp.℃ | 95~105 | 125~135 | 135~145 | 145~155 | 155~165 | 155~165 |
It can be processed on a wide range of commercially available cable fabrication equipment and screw types. A single flight PE metering screw with feed, transition and metering sections is recommended for most applications. Adequate output and torque limits are key determining factors for screw selection. A very low compression (1.2:1 type) screw can be used successfully if a breaker plate and 40/60 mesh screen pack are used to generate backpressure. Based on tests completed on 90mm, 25:1 standard extruder, the following typical conditions are recommended as a starting point. However, it may be necessary to optimize conditions for a given set of construction, extruder-screw configuration and tooling.
Packing | 25kgs/bag or customized |
Transport requirement | Keep away from the sunshine, rain and soaking during transport, as well as handle gently during carrying. |
Storage Environment | Clean, dry and ventilated warehouses. |
To be used | Within 12 months upon manufacturing date |